Deltapilot M FMB50 Compact version Sensor:
Contite measuring cell: absolute condensate tight and climatic proofed, long-term stable, minimum temperature effects Process connection:
All common hygienic connections, flanges and threads Span in bar/psi:
25mbar - 10bar
0.375psi - 150psi Process temperature:
-10 to +100°C +14 to +212°F
(+135°C /+275°F short term) Reference accuracy:
0.2% (standard) 0.1% (option)
Deltapilot M FMB51 Compact version Sensor:
Contite measuring cell: absolute condensate tight and climatic proofed, long-term stable, minimum temperature effects Process connection:
flanges and threads Span in bar/psi:
25mbar - 10bar
0.375psi - 150psi Process temperature:
-10 to +85°C Reference accuracy:
0.2% (standard) 0.1% (option)
Deltapilot M FMB52 Cable version with process connection Sensor:
Contite measuring cell: absolute condensate tight and climatic proofed, long-term stable, minimum temperature effects Process connection:
flanges and threads Span in bar/psi:
25mbar - 10bar
0.375psi - 150psi Process temperature:
with PE cable: -10…+70 °C with FEP cable: -10…+80 °C Reference accuracy: 0.2% (standard) 0.1% (option)
Deltapilot M FMB53 Cable version with suspension clamp/ mounting clamp Sensor:
Contite measuring cell: absolute condensate tight and climatic proofed, long-term stable, minimum temperature effects Process connection:
suspension clamp/ mounting clamp Span in bar/psi:
25mbar - 10bar
0.375psi - 150psi Process temperature:
with PE cable: -10…+70 °C with FEP cable: -10…+80 °C Reference accuracy: 0.2% (standard) 0.1% (option)
Deltapilot S
Deltapilot S FMB70 Compact hygienic version Sensor:
With Contite measuring cell, condensate proofed and long-term stable Process connection:
All common sanitary connections Span in bar/psi:
25mbar - 10bar
0.0375psi - 150psi Process temperature:
-10 to +100°C
+14 to +212°F
(+135°C /+275°F short term) Reference accuracy:
0.1% of the set span
Waterpilot
Waterpilot FMX21 Sensor:
Ceramic Output signal:
4…20mA/HART 6.0 Process connection:
Stainless steel mounting clamp; Stainless steel mounting screw Span in bar/psi
(gauge pressure):
100mbar - 20bar
1.5psi - 300psi Span in bar/psi
(absolute pressure):
2bar - 20bar
30psi - 300psi Diameter probe:
22mm (0.87inch) for drinking water applications
42mm (1.66inch) for waste water applications
29mm (1.15inch) for saltwater applications Accuracy:
0.2% of URV
0.1% of URV optional
Waterpilot FMX167 Sensor:
Ceramic Output signal:
4…20mA Process connection:
Stainless steel mounting clamp; Stainless steel mounting screw Span in bar/psi:
100mbar - 20bar
1mH2O - 200mH2O
1.5psi - 300psi
3ftH2O - 600ftH2O Diameter probe:
22mm (0.87inch) for drinking water applications
42mm (1.66inch) for waste water applications
29mm (1.15inch) for saltwater applications Accuracy:
0.2% of URV